Описание оборудования | |
---|---|
HF read/write head, ISO 15693, for IDENTControl, for hazardous areas | |
General specifications | |
Operating frequency | 13.56 MHz |
Transfer rate | 26 kBit/s |
Sensing range | |
UL File Number | E305142 |
Functional safety related parameters | |
MTTFd | 680 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
LED green/yellow | green: power on green flashing: read/write attempt performed yellow: data carrier detected |
Electrical specifications | |
Power consumption | ? 1.3 W |
Supply | from the IDENTControl |
Compliance with standards and directives | |
Directive conformity | |
Standard conformity | |
Approvals and certificates | |
UL approval | Class I, Division 1, Groups C, D |
FCC approval | This device complies with pИли отправьте нам запрос наeration is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Degree of protection | NEMA Type 4, 7, 9 |
Connection | Terminals |
Material | |
Installation | |
Mass | approx. 4080 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |