general data | |
---|---|
type | height |
version | PosCon OXH7 |
measuring range (width) | 48 … 72 mm |
measuring range (distance) | 100 … 150 mm |
measuring frequency | 570 Hz |
resolution | 2 … 4 µm |
linearity error | ± 30 … 90 µm |
temperature drift | ± 0,04 % Sde/K |
power on indication | LED green |
output indicator | LED yellow / LED red |
ethernet link indication | LED blue |
light source | pulsed red laser diode |
wave length | 656 nm |
laser class | 1 |
optical peak power max. | 3 mW |
adjustment | Webserver, Ethernet TCP/IP |
electrical data | |
response time / release time | 3,5 ms |
voltage supply range +Vs | 15 … 28 VDC |
current consumption max. (no load) | 150 mA |
switching output | push-pull |
output current | < 100 mA |
interface | Ethernet TCP/IP |
reverse polarity protection | yes, Vs to GND |
short circuit protection | yes |
protocol | Modbus TCP, OPC UA |
webserver | yes |
mechanical data | |
width / diameter | 26 mm |
height / length | 74 mm |
depth | 55 mm |
type | rectangular, front view |
housing material | aluminum |
front (optics) | glass |
connection types | connector M12 8 pin & M12 4 pin |
weight | 135 g |
ambient conditions | |
ambient light immunity | < 35 kLux |
operating temperature | -10 … +50 °C |
protection class | IP 67 |
storage temperature | -20 … +60 °C |
vibration (sinusoidal) | -20 … +60 °CIEC 60068-2-6:2008 1.5 mm p-p at f = 10 - 57 Hz, 10 cycles per axis 10 g at f = 58 - 2000 Hz, 10 cycles per axis |
shock (semi-sinusoidal) | -20 … +60 °CIEC 60068-2-6:2008 1.5 mm p-p at f = 10 - 57 Hz, 10 cycles per axis 10 g at f = 58 - 2000 Hz, 10 cycles per axisIEC 60068-2-27:2009 30 g / 11 ms, 6 jolts per axis and direction |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |